Cutting fluid chillers - line RLC |
|
|
|
Page 2 of 3
- TECHNICAL CHARACTERISTICS:
EQUIPMENT
- complete electrical box included on the RLC 120 cooler only.
- electronic control management of soluble oil temperature within the tank by piloting cooling compressor or resistance (option)
- heating resistance with 4 to 15 KW power, weak load: 4 W/cm2.(option)
HEATING
- hot and cold regulation, positioning of the resistance on the tank and control by RLC.
RLC 5 kW to 12 kW range
Technical characteristics –RLC 5 kW to 12 kW range
Model
|
RLC 50 |
RLC 80 |
RLC 100 |
RLC 120 |
| Cooling fluid |
R 404a |
R 404a |
R 404a |
R 404a |
| Cooling fluid mass (kg) |
3,100 |
3,100 |
3,300 |
3,300 |
| Electrical power supply |
400 V / 3 / 50Hz |
400 V / 3ph / 50Hz |
400 V / 3 / 50Hz |
400 V / 3 ph / 50Hz |
| Maximum pressure |
29 bar |
29 bar |
29 bar |
29 bar |
| Cooling power (emulsion 20/air 35) |
5 000 W |
8 000 W |
10 000 W |
12 000 W |
| External protection |
IP43 |
IP43 |
IP43 |
IP43 |
| Installed electrical power |
3 010 VA |
5 400 VA |
4 400 VA |
7 250 VA |
| Mass |
70 kg |
90 kg |
75 kg |
95 kg |
| Cutting oil temperature |
15 to 30°C |
15 to 30°C |
15 to 30°C |
15 to 30°C |
| Water circuit max. pressure |
0 bar |
0 bar |
0 bar |
0 bar |
| Ambient temperature |
15 to 45°C |
15 to 41°C |
15 to 43°C |
15 to 40°C |
| Noise level (dBA at 1m) |
72 |
72 |
72 |
72 |
RLC 15 kW to 50 kW range
Technical characteristics –RLC 15 kW to 50 kW range
Model
|
RLCS 150 |
RLCS 200 |
RLCS 250 |
RLCS 302 |
RLCS 402 |
RLCS 502 |
| Fluid to be cooled |
Cutting oil emulsion (4 - 6% oil), does not attack copper |
| Cooling fluid |
R 134a (1 cooling circuit) |
R 134a (2 cooling circuits) |
| Maximum pressure |
20 bar |
|
Cooling fluid mass
(copper evaporator)
|
5,500 kg |
6,500 kg |
7,500 kg |
2 x 5,500 kg |
2 x 6,500 kg |
2 x 7,500 kg |
|
Cooling fluid mass
(stainless steel evaporator)
|
6,500 kg |
7,000 kg |
7,500 kg |
2 x 6,500 kg |
2 x 7,000 kg |
2 x 7,500 kg |
| Electrical power |
400 V / 3 / 50 Hz |
| Installed electrical power |
6 570 W |
9 570 W
|
12 070 W |
12 740 W |
18 740 W |
23 740 W |
| Maximum current |
22,4 A |
29,4 A |
35,4 A |
43,8 A |
57,8 A |
69,8 A |
| Start up current |
125 A |
170 A |
201 A |
147 A |
198 A |
236 A |
|
Electrical supply Protection
(to be installed by client)
|
25 A |
32 A |
40 A |
50 A |
63 A |
80 A |
|
Cooling power
(Emulsion 22/Air 35)
|
15 000 W |
20 000 W |
25 000 W |
30 000 W |
40 000 W |
50 000 W |
|
Power consumption
(Emulsion 22/Air 35)
|
5 950 W |
8500 W |
10 640 W |
11 580 W |
15 880 W |
20 960 W |
|
External protection
|
IP 54 |
|
Mass
(copper evaporateur, all options)
|
290 kg |
310 kg |
330 kg |
550 kg |
600 kg |
650 kg |
| Cutting oil temperature |
15 à 30°C |
| Maximum pressure emulsion circuit |
0 bar |
| Ambient temperature |
15 to 45°C (own condensors, emulsion at 22°C) |
| Noise level (at 1m) |
70 dBA |
70 dBA |
72 dBA |
73 dBA |
73 dBA |
75 dBA |
|